RQ SERİES
The RQ-30 is a sensor for continuous discharge measurement of
rivers, open channels and canals with known cross-section profile.
The sensor uses innovative radar technology to measure velocity,
water level and discharge. It enables reliable, non-contact
measurement without the need for structural work in the water.
Non-contact, maintenance free measurement system
No structural work is necessary in the water
No threat to the system through flooding
Low power consumption enables operation using solar cells
Recognition of flow direction
Measuring range from +/- 0.10 to +/- 15 m/s (depending on the flow conditions)
Recognition of hysteresis-effects
Measurement in backwater situations
Measures even where weed growth prevails and sensor is not affected by turbidity
Measurement in tidal waters
Automatic angle measurement
Optional (RQ-30a): analogue outputs from 4 to 20 mA
SQ SERİES
The radar sensors of the SQ series continuosly measure
the discharge(flow) volume of sewer
systems, ducts, semi-filled pipes and
other technical channels in the fields of wastewater and
industrial effluents.
Due to the contact-free measurement
deposits and other solids in the water do not harm the
sensor. This is especially advantageous for
the measurement of wastewater.
The compact design allows an installation
in manholes or in sewage systems.
Size (mm) | 338 x 333 x 154 mm |
Total Weight | 5.4 kg |
Protection Class | IP 67 |
Power Supply | 6 ... 30 V |
Power Consumption | Approx. 1mA in standby mode at 12V source, approx. 140mA in active mode |
Working Temperature | - 35 ° ... 60 ° C |
Storage Temperature | - 40 ° ... 60 ° C |
Protection | High voltage protection, Reverse connection protection |
Level distance | 0 ... 6 m - Ultrasonic version (SQ Series) 0 ... 8 m - Radar version (SQ-8R Series) 0 ... 15 m - Standard version (RQ Series) 0 ... 35 m - Extra version (optional) (RQ Series) |
Resolution | 1 mm |
Sensitivity | +/- 2 mm |
The radar frequency is | 26 GHz (K-Band) |
Radar angle starting | 10 ° |
Water Velocity Range | 0.10 ... 15 m / s |
Water Speed Sensitivity | +/- 0.01 m / s; +/- 1% FS |
Water Flow Direction | +/- (bidiretion) |
Measurement Time | 5 ... 240 sec |
Measurement Range | 8 min. ... 5 hours |
Measurement Frequency | 24 GHz (K-Band) |
Radar angle starting | 12 ° |
Distance to water surface | 0.50 ... 35 m |
Calculable minimum water height | 3 mm |