AQUADATA CM-32
model Universal Current Meter used in
rivers, irrigation channels, seas,
in lakes, in water gutters, in drainage and evacuation
a flow rate used to measure water velocity in
measuring instrument.
Providing measurement even in the shallowest waters
as a complete set with different propeller variants
It is made. Universal Electronic Current Meter
as used in normal waters, in high waters
auxiliary measurement such as hanging train, donaw and cable car
with the help of a reel
Body
Made of stainless steel chrome steel.
With 2 precision bearings mounted on the shaft
the movement of the propellers is provided, the propeller
the sleeve is filled with oil and the plastic seal is mounted
to prevent water from entering the device
Pulse Formation with Magnet and Reed Contact
The magnet placed on the moving shaft,
fixed in body Reed In front of contact
a signal is generated in each pass.
Continuous pulsing every full revolution of the propeller
creation continues. The propeller is mounted
"non-friction" on shaft precision bearings
movement has increased the sensitivity of mulinenin. Reed
The contact mechanism is easy to change.
In shallow water up to a depth of 1 m.
it is possible to measure by entering the water. that
the pipe is placed on the bottom of the water. Current Meter device
are moved at regular intervals on the handle.
Roof-to-floor with ferrous floors is safe
they provide a sitting and the bottom is unnecessarily long
. Parallel to the flow of the sapphire
mini "direction indicator piece"
has. Universal Electronic Mulineler with 0.025 m /
sec. to max. 12 m / sec. flow rate measurement between
done.
Handle
2 m. Stems in the neck (two
pieces) made of stainless chrome-steel pipe.
Stems are spaced 10 cm apart for easy reading
It is a feature. 0 cm to 20 cm 1 cm. the beakers.
Cable
The number of revolutions seen with the return of the propeller in water
with a contact cable (3 m.)
Transmitted. The plugs on the cable ends are made of stainless chrome material.
Calculation of Flow Rate
The flow rate of the water is obtained according to the number of revolutions to be obtained at the end of the turn of the propellers. Speed achieved
The k and Δ parameters in the formula v = k.n + Δ used are determined when the instrument is calibrated. These parameters
and & quot; n & quot; values indicative of the speeds at the & quot; n & quot; speed are copied to the memory of the electronic numerator device
reported and reported
v = k. n +?
v = Water velocity (m / sec.)
k = hydraulic gradient of the propeller in water (m)
n = a round trip average of the propeller
Δ = According to the values obtained from the tests made on an open calibration channel of the Universal Mulleren
characteristic (m / sec.)
Constant values k and Δ due to mechanical differences in propeller and shaft bed between the Current Meters
channel (DSİ-TAKK).
Calibration values are given in tables with the current meter
Operating temperature | -20°C to +80°C |
Accuracy | Time : 0.01sec Number of Pulses : 1 pulse |
Max. Number of Pulses | 40puls/sec |
Time setting | 5 , 10 , 15 , .... 200 sec |
LCD Screen | 128x64 Graphics Dot Matrix |
Keypad | 6 Keys Keypad |
Battery | 3.7V Lithium Ion |
Interface | USB (used to charge the battery) |
Protection | IP65 |
Weight | Equipment including bag approx. 5.5 kg |