The resistive meter set ; transceiver and receiver units are on the same device;
* 2 rolls 500 m. current cable,
* 2 rolls 100 m. voltage cable,
* 4 chrome-nickel Electrodes,
* It consists of 2 pieces of copper sulphate pot and battery.
Resistivity meter is used for environmental geology, determination of depth of ground water table, depth of rock, change of soil structure, determination of landslides and determination of underground layers and mine exploration.
Operational depth:
400 to 500 m under normal conditions.
Ideal conditions are 1000 m.
Technicial Specifications
Power Supply: 12V. DC / 45 Ah. Battery.
Channel no: 1
Output Current: 10, 20, 50, 100, 200, 300, 400, 500 ... mA.
Input Impedance: 10 M? (Minimum).
Maximum Output Voltage: 50, 100, 150, 200, 500 V.
Sensitivity: 0.01%
Pulse Length: 0.1 to 4 seconds.
LCD Display: 4,5 Digit
Self Potential (SP):
Channel no: 1
Max. Input Voltage: ± 0 - 500 mV. Manual.
Sensitivity: 1%
Dimensions: 30 x 42 x 17 cm.
Overload: 10 kg.
Voltage Stage: 0,01 mV. with 1999 mV. (Automatic)
Maximum Output Power: 700 Watts